Our strategic partnership with Ingersoll Rand allows us to leverage innovative asset management solutions to better meet our sites’ needs while driving enhanced reliability, lowering Total Cost of Ownership, and improving energy efficiency. The wrap-around design protects the motor, and it’s plumbed to run 2 hoses at once, with a separate gauge for each hose, doubling your productivity by letting 2 people work at once…” The 120V electric motor gives you 4.4 CFM at 90 PSI. That secured it our ‘Best’ rating because it is great for various jobs such as trim, roofing, decking, framing, etc. “An Ingersoll Rand compressor speaks for itself with a reputation for durability and reliability - and this unit is no exception. Similarly, if the cooling fan intake grate or any other air pathways are clogged with gunk, the motor may overheat and cause the breaker to trip.What people are saying about Ingersoll Rand If this excess power draw exceeds the breaker’s capacity, it will trip the breaker. If your compressor’s air intake filter is clogged with dirt and dust, it can strain the motor, causing it to draw more amperage than normal. Reason #4 Dirty Air Filter or Cooling Components Let’s look at the possible causes of this. It’s typically more common for an air compressor to trip the breaker after running for a short time or as the motor kicks on a second time to maintain pressure in the air tank. Air Compressor Trips Breaker After Running for a Few Seconds (Or Longer) If so, you’ll likely be better off replacing the whole compressor. In some cases, the motor or pump may simply be on its last leg, particularly if it’s very old. Again, unless you have experience with this, you’re probably better off taking it to a motor/compressor repair specialist to have this done. If this doesn’t solve the problem, you’ll have to test the motor windings and capacitor(s) to ensure they’re working properly. Solution: With the compressor turned off and unplugged, check all electrical connections in the compressor head and tighten if necessary (your user manual should have instructions on how to do this). This issue may not always occur immediately on startup and may be accompanied by flickering/dimming lights. If you have multiple devices plugged into the same circuit, turning on your air compressor may simply put it over the edge – air compressors tend to draw a lot of power when the motor starts up. One of the most common causes of a tripped circuit breaker is a simple overload of the circuit. ( Note: this means when you initially turn it on, not when the pump kicks back on automatically during use – we’ll explore that scenario in the next section.) Reason #1 Your Circuit is Overloadedīefore looking at the air compressor itself, it’s best to rule out issues with your circuit. Air Compressor Trips The Breaker As Soon As It Startsįirst, let’s look at what might cause your air compressor to trip the breaker immediately on startup. With that in mind, we’ll examine the possible causes in each scenario separately. That being said, some issues may cause either an immediate or delayed trip. Does it happen as soon as you turn it on or after it’s been running for a few seconds or more? The answer may point you in the direction of the root cause. The first thing to keep in mind when troubleshooting a circuit breaker trip is when the breaker trips. This gives you some idea of what’s going on when your air compressor trips the breaker – it’s usually due to an overload or electrical fault of some kind. When an electrical anomaly or overload is detected, the breaker will automatically “trip,” cutting off power to the circuit. They are located in your electrical distribution board (aka breaker box). Air Compressor Tripping Breaker FAQ’s A Word On Circuit BreakersĪ circuit breaker is a switch designed to protect an electrical circuit (and the devices drawing power from it) from damage due to faults, shorts, or excessive current.Air Compressor Keeps Tripping Breaker Conclusion.Reason #9 Failed Unloader Valve or Check Valve.Reason #8 Damaged/Improperly Tensioned Belt.Reason #4 Dirty Air Filter or Cooling Components.Air Compressor Trips Breaker After Running for a Few Seconds (Or Longer).Reason #3 Short-Circuit/Failed Capacitor/Loose Wiring In Compressor.Reason #2 Faulty Circuit Breaker or Wiring Issue.Air Compressor Trips The Breaker As Soon As It Starts.So this article will cover the many possible reasons your air compressor is tripping your circuit breaker, how to diagnose them, and what to do about them. To make matters worse, there are numerous possible causes, many of which can be difficult to diagnose. Few things are as frustrating as trying to use your air compressor only to have your circuit breaker trip – especially if it happens over and over again.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |